menu back
  • Reliable 30+ years in the industry
  • Quality Manufactured by us
  • Sustainable 100% Natural Wood
  • Speedy Next Day Delivery Available

Stauf SPU-425 Adhesive 600ml Sausage

Accessories N/A

£8.00 incl. VAT

Product code: ST425/S
Product code: ST425/S

EXAMINATION OF SUBFLOOR
Prior to processing, the subfloor must be checked according to the standard DIN 18365 or corresponding national standards (e.g. BS 5325). The subfloor shall be resistant to pressure and tension, free of cracks, must have sufficient surface strength, be permanently dry, level, clean and free of from contaminants that may prevent adhesion, sinter layers etc. In addition, porosity and grip of surface need to be checked. Also check moisture content and absorption of subfloors as well as temperature, air humidity and subfloor temperature.
SUBFLOOR PREPARATION
It must be ensured that the subfloor is ready for installation by performing proper subfloor preparation, floors must be clean, have sufficient surface strength, must be level, permanently dry and free of cracks. A mechanical pretreatment of the subfloor (sweeping, vacuuming, mechanical brushing, sanding, milling, shot blasting) must be performed depending on type and condition of subfloor. Cracks and joints, except expansion joints and other construction joints, shall be solidly closed with STAUF repair resin and floor brackets. Cavities and indentations can be filled with a non self-levelling STAUF levelling compound. If necessary, make sure subfloors are level, have sufficient absorptive capacity and grip by applying the appropriate STAUF levelling compound.
PROCESSING
Place aluminum bag or cartridge into caulking gun and apply adhesive in stripes on sub floor or on backside of planks. Apply stripes with a clearance of approx. 8 cm diagonally to longitudinal direction of plank. Volume of applied adhesive ridge is adjustable by changing diameter of press nozzle. Applied volume increases with unevenness of sub floor and length of the planks. In particular with raw wood flooring, avoided pushing adhesive into joints. Depending on the degree of setting, adhesive residues can be removed with the appropriate STAUF cleaners. Please test the effect of the cleaner on the finish of the wood flooring in an inconspicuous area or on a sample prior to applying the cleaner. Hardened adhesive residues can easily be removed mechanically, mostly residue-free. However, longer exposures on finished wood flooring should be avoided to prevent possible contouring.

ACCESSIBILITY
Load bearing capacity depends on room climate and applied quantities of adhesive.
OTHER INFORMATION
The adhesive hardens when reacting with moisture either in the form of air humidity, wood or substrate moisture. The higher the ambient temperature, the faster the adhesive sets. Setting time increases with thickness of the adhesive layer. Plasticizers contained in the adhesive can cause flow asphalts to partially dissolve and may affect the wood flooring finish systems, especially for wood flooring installed without tongue and groove technique. Adhesives classified as elastic according to DIN EN 14293 and ISO 17178, have elastic properties once hardened. On account of this elasticity, only minimal tension is transferred from parquet to sub floor, but dimensional changes of the parquet elements are allowed for. Elastic adhesives are only recommended to a limited extent for bonding types of parquet flooring without tongue and groove joints because of their lower dimensional stability compared to hard-plastic or hard-elastic adhesives. These types of parquet flooring should preferably be bonded with hard STAUF reactive resin adhesives (PUK or SPU types) or hard-plastic dispersion adhesives (STAUF M2A types).
LIMITATION OF LIABILITY
The foregoing representations are based on the results of our most current product and material testing and are of a non-obligatory advisory nature only since we have no control over the actual quality of workmanship, materials used and worksite conditions. As such, they do not constitute an express or implied warranty of any kind. The same applies to our commercial and technical consultation services which are provided free-of-charge and without obligation. Therefore, we strongly recommend that prior on- site testing be conducted to observe and study the suitability of the product for the intended purpose. With the release of this technical information, all prior technical information (technical data sheets, installation recommendations and other information regarding similar purposes) becomes invalid.

EXAMINATION OF SUBFLOOR
Prior to processing, the subfloor must be checked according to the standard DIN 18365 or corresponding national standards (e.g. BS 5325). The subfloor shall be resistant to pressure and tension, free of cracks, must have sufficient surface strength, be permanently dry, level, clean and free of from contaminants that may prevent adhesion, sinter layers etc. In addition, porosity and grip of surface need to be checked. Also check moisture content and absorption of subfloors as well as temperature, air humidity and subfloor temperature.
SUBFLOOR PREPARATION
It must be ensured that the subfloor is ready for installation by performing proper subfloor preparation, floors must be clean, have sufficient surface strength, must be level, permanently dry and free of cracks. A mechanical pretreatment of the subfloor (sweeping, vacuuming, mechanical brushing, sanding, milling, shot blasting) must be performed depending on type and condition of subfloor. Cracks and joints, except expansion joints and other construction joints, shall be solidly closed with STAUF repair resin and floor brackets. Cavities and indentations can be filled with a non self-levelling STAUF levelling compound. If necessary, make sure subfloors are level, have sufficient absorptive capacity and grip by applying the appropriate STAUF levelling compound.
PROCESSING
Place aluminum bag or cartridge into caulking gun and apply adhesive in stripes on sub floor or on backside of planks. Apply stripes with a clearance of approx. 8 cm diagonally to longitudinal direction of plank. Volume of applied adhesive ridge is adjustable by changing diameter of press nozzle. Applied volume increases with unevenness of sub floor and length of the planks. In particular with raw wood flooring, avoided pushing adhesive into joints. Depending on the degree of setting, adhesive residues can be removed with the appropriate STAUF cleaners. Please test the effect of the cleaner on the finish of the wood flooring in an inconspicuous area or on a sample prior to applying the cleaner. Hardened adhesive residues can easily be removed mechanically, mostly residue-free. However, longer exposures on finished wood flooring should be avoided to prevent possible contouring.

ACCESSIBILITY
Load bearing capacity depends on room climate and applied quantities of adhesive.
OTHER INFORMATION
The adhesive hardens when reacting with moisture either in the form of air humidity, wood or substrate moisture. The higher the ambient temperature, the faster the adhesive sets. Setting time increases with thickness of the adhesive layer. Plasticizers contained in the adhesive can cause flow asphalts to partially dissolve and may affect the wood flooring finish systems, especially for wood flooring installed without tongue and groove technique. Adhesives classified as elastic according to DIN EN 14293 and ISO 17178, have elastic properties once hardened. On account of this elasticity, only minimal tension is transferred from parquet to sub floor, but dimensional changes of the parquet elements are allowed for. Elastic adhesives are only recommended to a limited extent for bonding types of parquet flooring without tongue and groove joints because of their lower dimensional stability compared to hard-plastic or hard-elastic adhesives. These types of parquet flooring should preferably be bonded with hard STAUF reactive resin adhesives (PUK or SPU types) or hard-plastic dispersion adhesives (STAUF M2A types).
LIMITATION OF LIABILITY
The foregoing representations are based on the results of our most current product and material testing and are of a non-obligatory advisory nature only since we have no control over the actual quality of workmanship, materials used and worksite conditions. As such, they do not constitute an express or implied warranty of any kind. The same applies to our commercial and technical consultation services which are provided free-of-charge and without obligation. Therefore, we strongly recommend that prior on- site testing be conducted to observe and study the suitability of the product for the intended purpose. With the release of this technical information, all prior technical information (technical data sheets, installation recommendations and other information regarding similar purposes) becomes invalid.

Product code: ST425/S

Species: n/a

Group: Accessories

Category: Adhesives


Brushed: n/a

Profile: n/a

Specification: n/a

Weight: 0.6 kg

Pack Size: 1

Type of finish : n/a

Unit Measurement : per Item


Have no product in the cart!
0